//測試代碼,打5003,會強制故意換成各種錯誤資料,測完移除二個function
public int QueryCurrentVID(int requestedVID, ref Dictionary<SecsItem.SecsIndexType, object> QueryList, object arg = null)
{
if (requestedVID == 5003) // Special handling for VID 5003 (Control_Mode)
{
// Cycle through test cases: 1, 2, ..., TOTAL_TEST_CASES_FOR_5003, then back to 1
testCaseCounterFor5003 = (testCaseCounterFor5003 % TOTAL_TEST_CASES_FOR_5003) + 1;

object valueToSet = null;
string testDescription = "";

switch (testCaseCounterFor5003)
{
case 1:
valueToSet = 300; // int, will cause overflow for U1
testDescription = "Integer Overflow (300)";
break;
case 2:
valueToSet = -1; // int, will cause overflow for U1
testDescription = "Integer Out of Range (-1)";
break;
case 3:
valueToSet = 256L; // long, will cause overflow for U1
testDescription = "Long Overflow (256L)";
break;
case 4:
valueToSet = 1000u; // uint, will cause overflow for U1
testDescription = "UInt Overflow (1000u)";
break;
case 5:
valueToSet = "ABC"; // string, cannot be parsed to byte
testDescription = "String Conversion Error (ABC)";
break;
case 6:
valueToSet = "280"; // string, numeric but out of byte range
testDescription = "String Numeric Out of Range (280)";
break;
case 7:
valueToSet = 123.45; // double, unsupported type for direct U1 conversion
testDescription = "Unsupported Type (double 123.45)";
break;
case 8:
valueToSet = null; // null value
testDescription = "Null Value Injection";
break;
case TOTAL_TEST_CASES_FOR_5003: // This should be 9 for the 9th case
default: // Default to a normal, valid case
valueToSet = (byte)1; // A valid byte value for U1 (e.g., "Online" or "Local")
testDescription = "Normal Valid Value (byte 1)";
if (testCaseCounterFor5003 != TOTAL_TEST_CASES_FOR_5003)
{
// If counter was unexpected, log it but still provide a normal value.
logger_SystemError.Error($"[QueryCurrentVID] TEST MODE FOR VID 5003: Unexpected counter value {testCaseCounterFor5003}. Defaulting to normal case.");
}
// No need to reset testCaseCounterFor5003 here, it will cycle naturally.
break;
}

// Using Warn level for test case injection logging to differentiate from actual system errors.
// This ensures these test-specific logs are noticeable but don't get mixed up with genuine errors
// if you filter logs by level.
logger_SystemError.Warn($"[QueryCurrentVID] TEST MODE FOR VID 5003: Injecting Case {testCaseCounterFor5003}/{TOTAL_TEST_CASES_FOR_5003} - {testDescription}. Value: '{TruncateValueForLog(valueToSet)}' (Type: {valueToSet?.GetType().FullName})");

// For VID 5003 (Control_Mode), the SECS type is U1 according to DefineValueList.json
QueryList[SecsItem.SecsIndexType.U1] = valueToSet;
return 0; // Return 0 to indicate success for the (test) query
}
else
{
// Original logic for all other VIDs
return OriginalQueryVIDLogic(requestedVID, ref QueryList, arg);
}
}
private int OriginalQueryVIDLogic(int requestedVID, ref Dictionary<SecsItem.SecsIndexType, object> QueryList, object arg)
{
Dictionary<int, VID> vidFile; // Ensure 'VID' is the correct type name for your VID definition objects
try
{
vidFile = jSecs.Read_VID(); // Method to read your VID definitions
if (vidFile == null)
{
logger_SystemError.Error($"[OriginalQueryVIDLogic] jSecs.Read_VID() returned null. Cannot process VID: {requestedVID}");
return -2; // Error code: Failed to load VID definitions
}
}
catch (Exception exReadVid)
{
logger_SystemError.Error($"[OriginalQueryVIDLogic] Exception while reading VID definitions (jSecs.Read_VID()) when querying for VID: {requestedVID}. Exception: {exReadVid.ToString()}", exReadVid);
return -2;
}

if (vidFile.TryGetValue(requestedVID, out VID vidDefinition)) // Use TryGetValue for safer access
{
// Ensure vidDefinition.Name and vidDefinition.ValueType are valid properties of your VID object
if (jSecs.QueryVidTable.TryGetValue(vidDefinition.Name, out var vidFunctionContainer)) // Replace 'var' with the specific type if known
{
try
{
// Ensure jSecs.Str2SecsIndexType dictionary and vidDefinition.ValueType are correct
if (jSecs.Str2SecsIndexType.TryGetValue(vidDefinition.ValueType, out SecsItem.SecsIndexType secsType))
{
// Ensure vidFunctionContainer.ReturnVidFunction is the correct way to invoke the function
// and that it's compatible with 'arg'
QueryList[secsType] = vidFunctionContainer.ReturnVidFunction.Invoke(arg);
logger.Debug($"[OriginalQueryVIDLogic] Successfully queried VID: {requestedVID} (Name: {vidDefinition.Name}), ValueType: {vidDefinition.ValueType}, SECSType: {secsType}, Value: '{TruncateValueForLog(QueryList[secsType])}'");
return 0; // Success
}
else
{
logger_SystemError.Error($"[OriginalQueryVIDLogic] Could not find SECS type mapping for ValueType '{vidDefinition.ValueType}' associated with VID {requestedVID} (Name: {vidDefinition.Name}).");
return -4; // Error code: SECS type mapping not found
}
}
catch (Exception exInvoke)
{
logger_SystemError.Error($"[OriginalQueryVIDLogic] Exception invoking ReturnVidFunction for VID {requestedVID} (Name: {vidDefinition.Name}, ValueType: {vidDefinition.ValueType}). Exception: {exInvoke.ToString()}", exInvoke);
return -5; // Error code: Exception during value retrieval function invocation
}
}
else
{
logger_SystemError.Warn($"[OriginalQueryVIDLogic] VID Name '{vidDefinition.Name}' (from VID {requestedVID}) was not found in jSecs.QueryVidTable.");
return -3; // Error code: VID name not registered in QueryVidTable
}
}
else
{
logger_SystemError.Warn($"[OriginalQueryVIDLogic] Requested VID {requestedVID} was not found in the loaded VID definitions (vidFile).");
return -1; // Error code: VID not defined
}
}